Marine & Offshore Cables

Dedicated Customer Teams & Industrial Services

We are ready to help meet your needs with quality products and competitive prices. Don’t hesitate to contact us for the best offer.

Download Brochure

Marine Cable Manufacturer for the Maritime Industry

PT PCM Kabel Indonesia is an Indonesian cable manufacturer providing marine cable solutions for shipboard electrical systems, shipbuilding projects, and offshore installations. PCM Cable offers various cable constructions designed for power distribution, lighting, control, and instrumentation applications in demanding maritime environments.

With manufacturing experience dating back to 1994, PCM Cable has developed specialized cable solutions to support the marine, transportation, energy, and infrastructure industries.

PCM marine cables are available in various constructions, including armoured, unarmoured, screened, and selected fire-resistant cable types. Each marine cable is selected according to technical specifications, electrical system requirements, and installation conditions aboard ships and offshore units.

Types of Marine Cables Available from PCM Cable

Different shipboard electrical systems require marine cables with specific functions and technical characteristics. PCM Cable offers a range of marine and offshore cable solutions to meet these requirements.

Marine Power and Control Cables

Marine power and control cables are used for electrical power distribution, lighting systems, and control circuits aboard ships and offshore installations.

PCM Cable offers products such as TLF-HF and TLSF-HF, featuring different cable constructions suitable for specific installation requirements.

Fire-Resistant Marine Cables

Certain shipboard electrical systems require cables designed to maintain circuit integrity during fire conditions under specified testing requirements.

PCM Cable’s marine cable portfolio includes fire-resistant variants such as TLF-FRHF and TLSF-FRHF. The applicable fire-resistance standards and performance characteristics should be verified using the technical documentation for each cable type.

Armoured and Screened Marine Cables

Armoured marine cables incorporate additional protective layers to provide mechanical protection for appropriate installation conditions.

Screened marine cables feature shielding designed to help reduce the effects of electromagnetic interference in specific applications.

PCM Cable offers marine cable constructions that can be selected according to installation requirements and project specifications.

Marine Control and Instrumentation Cables

Marine control and instrumentation cables are used to transmit control and measurement signals within shipboard electrical and monitoring systems.

Cable selection should consider operating voltage, conductor construction, shielding requirements, installation conditions, and applicable technical standards.

Marine Cable Applications in the Maritime Industry

Marine cables are essential components of electrical systems used aboard ships and offshore installations.

PCM marine and offshore cable solutions support applications such as:

  • Shipboard electrical power distribution

  • Marine lighting systems

  • Machinery and equipment control circuits

  • Instrumentation and monitoring systems

  • Offshore electrical installations

  • Electrical systems for shipbuilding and vessel maintenance projects

The suitability of each marine cable type depends on the electrical system, installation environment, and technical requirements of the project.

Marine Cable Technical Specifications

Selecting the appropriate marine cable requires more than determining conductor size or nominal voltage. Several technical factors must be evaluated to ensure compatibility with the intended application.

Important considerations include:

  • Conductor type and material

  • Rated operating voltage

  • Insulation and sheath materials

  • Armoured or unarmoured cable construction

  • Screening requirements

  • Operating temperature

  • Flame-retardant or fire-resistant characteristics

  • Applicable technical standards and testing requirements

PCM marine cables are available in different constructions and material configurations depending on the product type.

Selected marine cable variants feature tinned copper conductors, cross-linked polyethylene (XLPE) insulation, and SHF1 outer sheath materials.

Detailed information about cable construction, rated voltage, applicable standards, and product characteristics is provided in the technical specifications below.

Frequently Asked Questions About Marine Cables

What is the difference between marine cable and ship cable?

Marine cable and ship cable generally refer to cables designed for electrical installations aboard ships and in maritime environments. The term marine cable is commonly used in international engineering specifications and technical documentation.

What are marine cables used for?

Marine cables support electrical power distribution, lighting, control, instrumentation, and other shipboard electrical systems, depending on the cable type and its technical specifications.

Are all marine cables fire-resistant?

No. Marine cables have different fire-performance characteristics. Flame-retardant and fire-resistant properties serve different purposes and must be verified according to the applicable testing standards for each product.

How do I choose the right marine cable?

Marine cable selection should consider the electrical system, operating voltage, conductor size, cable construction, installation environment, and applicable project standards.

The relevant technical documentation should be reviewed before selecting a cable for a specific application.

Does PCM Cable provide marine cables for offshore applications?

Yes. PCM Cable offers Marine & Offshore Cables, including cable constructions intended for fixed installations aboard ships and offshore units, subject to the specifications and application requirements of each product.

Discuss Your Marine Cable Requirements with PCM Cable

Looking for a reliable marine cable manufacturer in Indonesia for shipbuilding, maritime electrical systems, or offshore projects?

PT PCM Kabel Indonesia provides marine cable solutions for power distribution, lighting, control, and instrumentation applications.

Contact our team with your cable specifications, operating voltage, conductor size, required quantity, and project requirements to discuss suitable product options.

Our Featured Products

 

TLF-HF
Unarmoured Lighting Power And Control Cable
0.6/1 kV

Construction

(IEC 60092-353, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-351)

Separator:

  • Non Hygroscopic Tape
  • On Request, Polyolefine plastic, SHF1

Outer Sheath:

  • Polyolefine plastic, SHF1
    (IEC 60092-360)
  • On Request, Thermosetting, SHF2
  • Standard colour black, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.

MAIN CHARACTERISTICS

RATED VOLTAGE
AC 0.6/1 kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)

MAXIMUM CONDUCTOR TEMPERATURE
+ 90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLF-FRHF
Fire-resistant Unarmoured Lighting Power And Control Cable 0.6/1 kV

Construction

(IEC 60092-353, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-351)

Separator:

  • Non Hygroscopic Tape
  • On Request, Polyolefine plastic, SHF1

Outer Sheath:

  • Polyolefine plastic, SHF1
    (IEC 60092-360)
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
AC 0.6/1 kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLSF-HF
Armoured Lighting Power And Control Cable 0.6/1 kV

Construction

(IEC 60092-353, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-351)

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour black, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.

MAIN CHARACTERISTICS

RATED VOLTAGE
AC 0.6/1 kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLSF-FRHF
Fire-resistant Armoured Lighting Power And Control Cable 0.6/1 kV

Construction

(IEC 60092-353, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-351)

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
AC 0.6/1 kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLEFSF-HF
Screened Armoured Power, Lighting And Control Cable 0.6/1 kV

Construction

(IEC 60092-353, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-351)

Screened:

  • Polyester, Aluminium Tape With Tinned Copper Drain Wire

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour black, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.

MAIN CHARACTERISTICS

RATED VOLTAGE
AC 0.6/1 kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLEFSF-FRHF
Fire-resistant Screened Armoured Power, Lighting And Control Cable 0.6/1 kV

Construction

(IEC 60092-353, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-351)

Screened:

  • Polyester, Aluminium Tape With Tinned Copper Drain Wire

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
AC 0.6/1 kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLF-HF
Unarmoured Control And Instrumentation Cable
150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Separator:

  • Non Hygroscopic Tape
  • On Request, Polyolefine plastic, SHF1

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour grey, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250 V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLF-FRHF
Fire-resistant Unarmoured Control And Instrumentation Cable 150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Separator:

  • Non Hygroscopic Tape
  • On Request, Polyolefine plastic, SHF1

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250 V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLSF-HF
Armoured Lighting, Control And Instrumentation Cable 250V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour grey, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION

TLSF-FRHF
Fire-resistant Armoured Control And Instrumentation Cable 150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250 V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLEFSF-HF
Armoured Pair Instrumentation And Communication Cable 150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Twisted Pair:

  • Two Insulated Core Twisted Together To Form A Pair

Screened:

  • Polyester, Aluminium Tape With Tinned Copper Drain Wire

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour grey, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLEFSF-FRHF
Fire-resistant Armoured Pair Instrumentation And Communication Cable 150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Twisted Pair:

  • Two Insulated Core Twisted Together To Form A Pair

Screened:

  • Polyester, Aluminium Tape With Tinned Copper Drain Wire

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250 V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLEFSF-HF(i)
Armoured And Individually Screened Instrumentation And Communication Cable 150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Twisted Pair:

  • Two Insulated Core Twisted Together To Form A Pair

Individual Screened:

  • Polyester Tape, Tinned Copper Braided
  • On Request, Copper Wire Braided

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour grey, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

TLEFSF-FRHF(i)
Fire-resistant Armoured And Individually Screened Instrumentation And Communication Cable 150/250 V

Construction

(IEC 60092-376, Design)

Conductor:

  • Tinned Copper Wire
    (IEC 60228, Class 2 or Class 5 on request)
  • On Request, Annealed Copper Wire

Fire Proof:

  • Mica Glass Tape

Insulation:

  • Crosslinked Polyethylene (XLPE)
    (IEC 60092-360)

Twisted Pair:

  • Two Insulated Core Twisted Together To Form A Pair

Individual Screened:

  • Polyester Tape, Tinned Copper Braided
  • On Request, Copper Wire Braided

Inner Sheath:

  • Polyolefine plastic, SHF1
  • On Request, Non Hygroscopic tape

Armour:
(IEC 60092-350)

  • Galvanized steel wire braid, Coverage 90%
  • On Request, Plain Copper or Tinned Copper braid

Outer Sheath:
(IEC 60092-360)

  • Polyolefine plastic, SHF1
  • On Request, Thermosetting, SHF2
  • Standard colour orange, other colours on request

APPLICATION:

For fixed installation in most areas and on open deck in ships and offshore unit.
If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

MAIN CHARACTERISTICS

RATED VOLTAGE
150/250 V (300V)

MAXIMUM CONDUCTOR TEMPERATURE
+90°C

FLAME-RETARDANT
IEC 60332-1-2 test for single insulated wire and cable
IEC 60332-3-22 test for bunched wire and cables category A

FIRE-RESISTANCE
IEC 60331-1 or IEC 60331-2

HALOGEN-FREE
IEC 60754 series

SMOKE EMISSION
IEC 61034 series

Contact PCM Cable for marine cable product information, technical assistance, and quotation requests.

Phone 1: (021) 5937-1728

Phone 2: (021) 5937-1729

Email: sales@pcmcable.com

Instagram: pcm.cable